Browse all practice questions for the ESCO Commercial Refrigeration Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ESCO Commercial Refrigeration Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • A TXV with an external equalizer is used on
  • Capillary vs TXV: Compare a capillary tube to a TXV in terms of control and efficiency.
  • Walk-in cooler investigation shows ice on the evaporator, evaporator superheat of 22°, suction and discharge pressures are low, and condenser subcooling is 2°. What is the most likely issue?
  • What valve is used to connect multiple evaporators of different temperatures to a single compressor?
  • What is the primary function of a condenser in the refrigeration cycle?
  • In a refrigeration control circuit, what is the function of a contactor?
  • A severe evaporator freeze up may cause which condition?
  • A walk-in freezer cycles on and off with an accumulator in the liquid line and ice forming from the liquid line solenoid to the expansion valve. The low-pressure switch closes prematurely. What is causing this condition?
  • The refrigerant condensing temperature in a water cooled condenser is normally about _____ higher than the leaving water.
  • In a parallel compressor rack system, what header is typically shared?
  • In a system with a capillary metering device, what effect does using a larger filter dryer have on startup current draw?
  • When the compressor service valve is back seated, which port closes?
  • Explain electric defrost and hot-gas defrost methods.
  • The type of compressor that allows access to the internal components is the
  • Cooling towers that pass air over water to remove system heat are limited in capacity by
  • Which instrument is commonly used to measure low-side refrigerant pressure in the field?
  • For walk-in coolers needing a high moisture content, the typical evaporator TD is
  • What is the function of a thermostat or digital controller in a display case?
  • An evaporator used to chill liquids is operating within normal superheat setting, but the system is not cooling the product properly. What is most likely the cause?
  • Which statement about refrigerant oil is correct?
  • In a dry type evaporator, achieving boil-off near the end of the coil improves which aspect?
  • What is the effect of insufficient heat rejection on the refrigeration cycle?
  • What is the proper procedure for cleaning condenser coils and why?
  • What is the function of the evaporator pressure regulator valve?
  • If an oil separator is not used, what should be installed in every vapor carrying line?
  • Dry type evaporators operate most efficiently with a superheat setting of approximately
  • In a parallel compressor rack system, which header is typically common to all compressors?
  • What is a key safety precaution when handling refrigerants to avoid injury?
  • An off-cycle defrost method is often used on evaporators operating at a minimum of what temperature?
  • When measuring oil pressure on the compressor with a pressurized oiling system, how is actual oil pressure determined?
  • Why is it important to know the refrigerant type when servicing a system?
  • In flooded evaporator setups, a _____ type device is used to maintain the liquid level.
  • In a dry type evaporator, where must liquid refrigerant boil off to maximize efficiency?
  • Why is inert nitrogen purging used during brazing?
  • Name two main condenser types used in commercial refrigeration.
  • On a multi circuit evaporator, if one circuit has a higher superheat than the others, this could be caused by
  • What is the purpose of a low-pressure switch in a refrigeration system?
  • At what evaporative temperature does an icemaker begin to make ice?
  • Defrosting a low temperature evaporator can be accomplished by
  • What device is used to check for parallel misalignment of a motor coupling?
  • How is a defrost cycle typically terminated in most reach-in refrigerators?
  • The term refrigerant conditions refers to which states?
  • Expendable refrigerant means
  • After completing service work on a refrigerator, the compressor service valves should be in which position?
  • The oil return orifice inside a suction line accumulator is designed to
  • Which action best helps determine whether a refrigerant system is correctly charged relative to its nameplate?
  • In low temperature refrigeration applications (excluding ice makers), box temperatures normally fall within which range?
  • What is a zeotropic blend, and how does it affect system charging and cycle behavior?
  • What pH level is considered neutral and desirable for ice machine or cooling tower applications?
  • What valve is used to prevent evaporator pressure from falling below a set limit?
  • What is the purpose of refrigerant recovery equipment?
  • What issue is indicated by moisture under the flare nut causing a slow refrigerant leak after repeated freezing and thawing?
  • A dirty evaporator and subsequent low evaporator pressures will cause
  • If a system has a long suction line riser, an oil trap should be installed every how many feet of vertical rise?
  • Starting at the compressor discharge, what is the next component in the basic cycle?
  • Which observation most strongly supports that an evaporator is starved for refrigerant?
  • In a typical system, where is the oil separator located?
  • An expansion device that is stuck open will cause
  • Which component maintains superheat in the evaporator?
  • High temperature refrigeration applications typically provide box temperatures in which range?
  • Some special applications use a flooded evaporator (operated full of refrigerant) to maintain the proper level of liquid refrigerant. What type of device is used?
  • Which refrigerant line is most sensitive to improper sizing?
  • Which method is NOT typically used to locate leaks in a charged system?
  • What symptom is commonly associated with TXV hunting?
  • A low temperature evaporator used for cooling space or product refrigeration should be defrosted periodically. Which option completes the statement?
  • Why is suction line insulation important?
  • Describe a systematic approach to troubleshooting a malfunctioning refrigeration system.
  • What device protects the high-pressure side from excessive pressure?
  • Which statement best describes the purpose of lockout/tagout procedures in service work?
  • Which component is often placed in the suction line to help prevent flood back into the compressor after hot gas termination?
  • Which four components form the basic vapor-compression refrigeration cycle?
  • Dry type evaporators operate most efficiently with superheat in which range?
  • A properly functioning condenser will first de-superheat, then sub-cool. Which option best describes this sequence?
  • In an air-cooled condenser, the refrigerant temperature is typically higher than ambient air by about how many degrees Fahrenheit?
  • Medium temperature refrigeration applications will normally provide box temperatures of which range?
  • Name three common compressor types used in commercial refrigeration.
  • A hot gas defrost cycle can be initiated by a?
  • In a TXV system, which two measurements does the valve respond to?
  • The 'low ambient control' is used to control which parameter?
  • If five frozen food cases iced up on a single compressor, what is the most likely fault?
  • What is the recommended next step after implementing corrective actions in a malfunctioning refrigeration system?
  • Which step should you take after verifying safety and power in troubleshooting a refrigeration system?
  • Excessive frost on the evaporator causes which result?
  • The relationship between low side absolute pressure and high side absolute pressure is called?
  • On a rack of multiple compressors, which device controls each individual compressor?
  • Workable head pressure during periods of low ambient temperature can be achieved by using
  • To control scaling in cooling towers, operators perform periodic what?
  • What is the normal operating position for a compressor service valve?
  • Water cooling towers require a periodic blow down to control
  • What is the purpose of a refrigerant recovery machine?
  • Which system is usually required for ultra low temperature applications?
  • Capacity control of a large compressor can be performed with?
  • The symptoms described include the compressor shutting off on the oil pressure switch, the oil sightglass being half full, and suction pressure at 3 psig. What is the most likely cause?
  • A custom reach-in freezer had a burned-out compressor replaced; evaporator seemed starved for refrigerant; liquid line was sweating after a filter dryer replacement. What is the most likely cause?
  • Why should an oil separator be kept warm in refrigeration equipment?
  • Why do suction line filter dryers have two service ports?
  • Which sequence of actions occurs in a properly functioning condenser?
  • A ______ is usually required for ultra low temperature applications.
  • Which national code governs electrical installations in the United States?
  • In a supermarket with a rooftop condenser, five low-pressure controls open and the liquid receiver is full, with the hot gas discharge line cold. What is the most likely cause?
  • The difference between the refrigerant's boiling temperature inside the evaporator and the evaporator outlet temperature is known as
  • In the vapor-compression cycle, what is the correct sequence from compressor discharge to return?
  • Which temperature marks the onset of ice production in an icemaker?
  • Which tool is used to verify parallel misalignment between a motor and its coupling?
  • The crankcase heater is used to prevent what during the off cycle?
  • Vibration eliminators should be installed _______ to the compressor crankshaft centerline.
  • Bubbles or foaming in the compressor's oil sight glass are an indication of which condition?
  • What is the purpose of oil traps in vapor lines?
  • Cryogenics refers to refrigeration systems operating at what temperature range?
  • Medium temperature refrigeration applications will normally provide box temperatures of
  • During a defrost, moisture was found under the flare nut on the evaporator side of the expansion valve, leading to a slow refrigerant leak after repeated freezing and thawing. What was the root cause?
  • Blended refrigerants should be charged into a running system
  • During maintenance, what is the recommended position of the compressor service valves to reduce the risk of leakage?
  • Which statement about condenser types is true?
  • To achieve peak efficiency and performance in a capillary tube system, the system must be
  • "Pump down" means to capture system refrigerant in the
  • Which safety precautions are essential during brazing or soldering copper refrigerant piping?
  • The two manually adjust the parameters of a high-pressure switch are
  • A refrigeration system that uses the evaporator of the first stage to exchange heat with the condenser of the second stage refrigeration system is called a
  • How should blended refrigerants be charged into a system?
  • Which statement best describes how defrost termination is typically determined?
  • Why is evaporator coil airflow critical for performance?
  • An automatic pumpdown system requires a
  • Why is system cleanliness important during maintenance?
  • Which code should be followed for electrical installations in the United States?
  • A TXV with an external equalizer is typically used on evaporators with what characteristic?
  • Low ambient temperatures seriously affect which type of units?
  • What is the purpose of an oil separator?
  • After replacing the filter dryer, the system is evacuated. Why is it important to remove air and moisture from the system?
  • The thermostatic expansion valve maintains what in the evaporator?
  • On an expansion valve refrigeration system, a low pressure control can indirectly be used for what purpose?
  • In a five-compressor rack where all low-pressure controls are open, which fault is most consistent with the observed symptoms?
  • Evaporator superheat is defined as the difference between the refrigerant's boiling temperature inside the evaporator and the temperature at the evaporator outlet.
  • Which cooling system component's performance is significantly affected by low ambient temperatures?
  • When measuring evaporator superheat on a long suction line, the pressure reading should be taken at the
  • Which statement best describes the behavior of zeotropic blends during evaporation and condensation?
  • Short cycling in a pumpdown system is most likely caused by a leaking which component?
  • Which component is designed to prevent refrigerant migration to the crankcase during the off cycle?
  • Cooling towers that pass air over water to remove system heat are limited in capacity by which factor?
  • Which is a common sign of a refrigerant leak?
  • Which component primarily regulates refrigerant flow to the evaporator?
  • What vacuum level is typically required to evacuate a refrigeration system before charging?
  • What is a common method to defrost a low-temperature evaporator?
  • Superheat measurements are best taken
  • What is the function of a condenser fan motor?
  • After a defrost cycle ends, the evaporator fans will
  • In a vending machine with a capillary metering device, after replacing the filter dryer and evacuating, the system shows low suction and head pressures with low motor amps. Which could be the cause?
  • In a low-ice-production cube ice machine, with a harvest solenoid and a thermostatic expansion valve, and a water reservoir at 32°F, the harvest solenoid shows a temperature rise of about 10°F and suction is slightly elevated. What is the faulty component?
  • What are typical applications for R-404A and R-134a in commercial refrigeration?
  • What does EPA Section 608 regulate for technicians?
  • Liquid slugging of the compressor can be caused by which condition?
  • Head pressure control valves permit hot gas to travel directly to which component?
  • In a system with several evaporators at different temperatures, which valve arrangement allows them to share one compressor?
  • When the defrost cycle is terminated, the evaporator fans will?
  • What is the typical supply voltage for many commercial refrigeration systems in the U.S.?
  • In a water-cooled condenser, the condensing temperature is typically about how many degrees Fahrenheit higher than the leaving water?
  • The oil separator is installed in which line?
  • Which indicators suggest a system may be undercharged?
  • An oil pressure differential switch utilizes which pressures in opening the time delay heater?
  • Which of the following determines the viscosity of refrigeration oils used in refrigeration systems?
  • Name two common strategies to improve energy efficiency in commercial refrigeration.
  • How does a thermostatic expansion valve regulate refrigerant flow?
  • The refrigerant and an air cooled condenser will normally contends at approximately _____ higher temperature than the air passing over it.
  • To adjust a water cooled condenser for design condensing temperature, you would:
  • Subcooling is the liquid refrigerant temperature below its condenser saturation temperature; what is one benefit of higher subcooling?
  • How is defrost termination typically determined?
  • What is the role of oil in a refrigeration system, and what happens if oil returns poorly?
  • What is the major difference between a cooling tower and an evaporative condenser?
  • Why is heat rejection to ambient necessary in the refrigeration cycle?
  • Which instrument is used to verify refrigerant pressure on the low side?
  • The suction accumulator prevents flood back from which condition?
  • Which defrost cycle uses hot gas to melt frost and can be initiated by a timer?
  • If a walk-in cooler requires a high percentage of moisture in the air due to the product being stored, the logical evaporator TD would be
  • Which of the following can serve as metering devices in a basic vapor-compression cycle?
  • Multiple compressors provide
  • Which tool is commonly used to locate leaks in a charged refrigeration system?
  • For accurate evaporator superheat measurements on long suction lines, the pressure is read at which component?
  • Which device senses superheat to control refrigerant flow in the evaporator?
  • A sequence of five frozen food cases operated by one compressor results in all five cases iced up. What is the likely problem?
  • A system using an automatic expansion valve (AEV) is not cooling and runs continuously. The gauges reveal low head pressure, but the suction pressure is acceptable. This could be caused by
  • Which term describes capturing refrigerant in the condenser and/or liquid receiver during operation?
  • What should you do if a system won't restart after a lockout?
  • A water regulating valve used to control water flow in a water cooled condenser application can be most accurately adjusted by
  • Why is nitrogen purge commonly used when evacuating lines?
  • Low temperature refrigeration applications, other than ice makers, normally provide box temperatures of which range?
  • Why must refrigerants be handled as hazardous materials and what precautions apply?
  • An ice machine auger makes a loud noise and the overload trips after resetting; the motor is very hot. The indicated cause is the lack of water flow. What is the correct explanation?
  • What term describes a thermostatic expansion valve that creates an unstable suction pressure?
  • Too low superheat increases the risk of what?
  • What symptoms indicate a malfunctioning condenser fan motor?
  • What time interval is required between each superheat adjustment?
  • Which compressor type allows access to its internal components for servicing?
  • What is a sight glass and what are its limitations?
  • In capillary tube systems that use suction line heat exchangers, when should the superheat reading be taken?
  • The effect of an inefficient water cooled condenser will
  • An evaporator pressure regulator valve (EPR valve) is a mechanical control that
  • To achieve a 15 psig cut-out when the cut-in is 40 psig, what differential setting is required?
  • Which of the following is NOT a metering device in a basic vapor-compression cycle?
  • Which pressures are used by an oil pressure differential switch to operate its time delay heater?
  • How is pressure–temperature data used when charging a system?
  • What action should be performed first when a refrigeration system won't restart after a lockout?
  • Esther-based oils are considered what type?
  • Which device limits evaporator pressure to a predefined minimum value in some systems?
  • If an oil separator is not used, what should be installed in all vapor carrying lines?
  • What factors lead to evaporator frost buildup?
  • What type of oil is used with HFC refrigerants?
  • If an accumulator is holding liquid refrigerant, what effect does this have on system operation?
  • Esther-based oils are which type?
  • Which PPE should be used when handling refrigerants or brazing?
  • What is the primary reason to clean condenser coils?
  • What instrument is typically used to measure the vacuum level in microns during system evacuation?
  • When retrofitting a CFC/mineral oil system to an HFC-based refrigerant, what is required?
  • Which two terms describe the manually adjustable settings on a high-pressure switch?
  • Which component is specifically designed to meter the return of liquid refrigerant and oil to the compressor?
  • Superheat is the temperature rise of refrigerant vapor above its saturated temperature at the suction pressure; what is its primary purpose?
  • Automatic pump down systems are used to prevent which condition?
  • What is a key limitation of the sight glass in modern systems?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy